Ratings and Specifications for Bestact Reed Element

@

Application

Medium Capacity Type

Large Capacity Type

Remarks

Heavy


Duty

General


Purpose

Heavy


Duty

Type

R25U

R14U

R15U

Contact Arrangement

1NO

1NO

Contact Performance Rated Continuous Current

3A

5A

Inductive Load
Rated Operational Current *1 (NEMA Pilot Duty) AC

240V 0.5A (180W)

240V 1A (360W)

Inductive load time constant:
40ms for medium capacity
100ms for large capacity
DC

115V 0.3A
(69VA)

115V 0.3A,
230V 0.2A (69VA)

Maximum Making Current *2

240VAC 15A

240VAC 30A

Power factor 0.7
Maximum Breaking Current *3

240VAC 15A

240VAC 30A

Power factor 0.4

115VDC 0.5A

115VDC 0.6A 230VDC 0.4A

115VDC 0.6A 230VDC 0.4A

Time Constant:
40ms (medium capacity)
100ms (large capacity)
Min. Operational Power Ratings

24V 1mA *5

1V 1mA

24V 1mA *5

Withstand Voltage
Across Contacts

500VAC, 1 minute

800VAC, 1 minute

Insulation Resistance

109 W or greater

109 W or greater

with 500VDC megger
Initial Contact Resistance

500mW or less

100mW or less

500mW or less

6VDC 1A
Capacitance

0.5 PF or less

0.45 PF or less

Operating Characteristics Pick-up Magnetmotive Force

100 to 130A (AT)

180 to 230A (AT)

Standard coil is of 300 turns, 33mm long, 10.5mm I.D with 0.2mm dia. Wire
Drop-out Magnetmotive Force

50A (AT) or greater

60A (AT) or greater

Operating Time

4ms or less (Bounce Excluded)

5ms or less (Bounce Excluded)

at 150% of pick-up ampere turn using standard coil
Releasing Time *4

2ms or less

3ms or less

Maximum Bounce Time

2ms

2ms

Mechanical Performance Mechanical Life

Over 100,000,000 Operations

50,000,000 Operations

Over 100,000,000 Operations

Vibration Resistance

147m/s2 (15G) or greater

196m/s2 (20G) or greater

20 to 1000 Hz
Impact Resistance

196m/s2 (20G) or greater
[980m/s2 (100G) or greater]

392m/s2 (40G) or greater
[980m/s2 (100G) or greater]

Value in brackets indicates breakdown G
Terminal Drawing Force

98N (10kgf)

98.0N (10kgf)

Ambient Temperature Operating Temperature

-50 to +150C

-50 to +150C

Storage

-60 to +180C

-50 to +160C


*1 Where 240VAC, the rated operational current is set at 10 times this value upon making (PF: 0.6 to 0.7) and 1 times this value upon breaking (PF 0.3 to 0.4). Rated operational current 1A means 10A making and 1A breaking. Where 115VDC is indicated, the current is set at 1 times making and 1 times breaking.

*2 The maximum making current complies with JIS C 4531, and enables 100 times making at a power factor of PF: 0.7.

*3 The maximum breaking current, by referring to JIS C 4531, is based on switching 25 times at PF: 0.4 (AC), time constant t = 100ms (DC) for either 115/230VDC cases for the large capacity element. For the medium capacity element, switching 25 times at PF: 0.4 (AC), time constant t = 40ms for 115VDC case only.

*4 The breaking time indicates the value when the coil is equipped with a flywheel diode.

*5 In circuit with optcoupler, 5V 10mA can be used.