CompanyProfile

Contact Us

DOWNLOAD

Ratings and Specifications for Limit Switches


Heavy Duty Limit Switches

Type of
Actuation

Roller
Lever

Cylindrical Roller Lever

Pull
Lever

Pull Lever
(Crane Drum)
Over-Winding
Protection

Fork Lever

Pull Lever (One Direction Pull)

Horizontal Mounting

Vertical Mounting

Type *1

PSKU-#R25A_

PSKU-# R25AB

PSKU-#R25AV

PSKU-#R25AE

PSKU-#R25AO

PIKU-#R25A_

PIKU-#R25AE

Switch Action

Spring Return

Maintained

Contact


Arrangement
Available *2

1NO (2-way operations)


1NC *3 (1-way operation
2NO (2 way operations)
1NO1NC *3 (1-way operation
2NC *3 (1-way operation)

1NO, 1NC, 2NO, 1NO1NC, 2NC (1-way operation)

1NO


2NO
1NO1NC *4

1NO, 1NC, 2NO, 1NO1NC, 2NC, (1-way operation)

Common


Specifications

Enclosure: Floodtight type (IP56) *5
Rated insulation voltage: 250V
Rated continuous current: 3A
Operational power ratings: 240VAC 0.5A, 115VDC 0.3A, 48VDC 0.5A
Withstand voltage: 500VAC for 1 minute across contact, 1500VAC for 1 minute across contact to ground
Operating temperature: -10 to +80°C
Storage Temperature: -25 to +90°C
Maximum recommended speed of actuation: 100m/min *6
Operating frequency: 3600 times/hour
Mechanical life: 5,000,000 operations or greater
Electrical life: 240VAC 5A making 0.5A breaking, 1,000,000 operations or greater (inductive load),
115VDC 50mA, 5,000,000 operations or greater (inductive load)
Lead-in method: PF 1/2 (13 diameter hole)

Notes:
*1 Types with # such as PSKU-#R25A can vary depending upon the contact arrangement 1NO [100], 1NC [010], 2NO [200], 2NC [020], 1NO1NC [110]
*2 Change of NO contact to NC contact connot be done at user.
*3 The lever movement is limited to either clockwise or counterclockwise operation. When ordering, specify the lever moving direction. For the 1-way operation of 1NO1NC, or 2NC, specify "R" at the end of the part number if CW is required or "L" for CCW.
*4 Where contact arrangement is 1NO and 2NO, specify the operating direction required. If it should turn on in CW operation, specify "R" at the end of the part number. Specify "L" for CCW.
*5 Type PSKU-#R25AO for crane drum over-winding protection will not restrict. However, after the contact has turned off, effective measures should be taken to lessen the effect of accidental turn on due to shock or vibration.
*6 Heat-resistant, corrosion-resistant type PSDH is available on order.


Floodtight Type Limit Switches
Type

PSPE-05E1

PSPE-05E2

Contact Arrangement

1NO

1NC

Incorporated Bestact Type

R15U

Operation Characteristics Pretravel

3.5mm or less

Overtravel

6.0mm or greater

Total Travel

9.0mm or greater

Release Position

1.5mm or greater

Operating Force

2.1kgf or less

Operating Frequency

3600 times/hour

Rated Insulation Voltage

250VAC

Rated Continuous Current

5A

Operational Power Ratings

240VAC 1.0A, 115VDC 0.5A

Maximum Making Current

240VAC 30A (PF: 0.7)

Insulation Resistance

100MW or greater (with 500V megger)

Withstand Voltage Across Contacts

800VAC for 1 minute

To Ground

1500VAC for 1 minute

Service Life Mechanical

5,000,000 operations

Electrical *1

240VAC 5A making 0.5A breaking (PF: 0.4) over 1,000,000 operations

115VAC, relay coil load (36mA) over 5,000,000 operations

230VAC, relay coil load (146mA) over 5,000,000 operations

115VDC, relay coil load (50mA) over 5,000,000 operations

Shock Resistance

294m/s2 (30G) or greater

Vibration Resistance

49m/s2 (5G) or greater (15 to 200 Hz)

Ambient Temperature Operating

-10 to +60°C (excluding icing)

Storage

-25 to +70°C

Enclosure

Floodtight/Oiltight IP57


*1: For application to DC circuit, connect the black lead to (+) and the white lead to (-).

Home